Update serial line authored by Pressl, Štěpán's avatar Pressl, Štěpán
......@@ -32,7 +32,16 @@ Connector Connector [NS25-W4P](https://www.tme.eu/cz/details/ns25-w4p/signalove-
| 3 | VCC |
| 4 | RxD |
### RS-232
### Serial line
It's not the same as TTL console because of control signals. To use all the features of the serial line, USART peripheral must be used (not UART).
Pins:
- RXD0 (PB0)
- TXD0 (PB1)
- CTS0 (PB2)
- RTS0 (PB3)
#### RS-232
Connector [NS25-W5P](https://www.tme.eu/cz/details/ns25-w5p/signalove-konektory-raster-2-54mm/ninigi/)
|Pin on PCB | Signal | DB9 | PC Signal | DB25 | DB9 |
......@@ -43,7 +52,7 @@ Connector [NS25-W5P](https://www.tme.eu/cz/details/ns25-w5p/signalove-konektory-
| 4 | CTS | 7 | RTS | 4 | 7 |
| 5 | GND | 5 | GND | 7 | 5 |
### RS-485
#### RS-485
Connector [NS25-W2P](https://www.tme.eu/cz/details/ns25-w2p/signalove-konektory-raster-2-54mm/ninigi/)
|Pin| Signal |
......
......