Commit e5886ab8 authored by Ille, Ondrej, Ing.'s avatar Ille, Ondrej, Ing.

doc: Datasheet updates.

parent d34f9962
Pipeline #19794 passed with stages
in 20 minutes and 1 second
......@@ -2657,7 +2657,7 @@ ISO11898-1 2015 defines three implementation types of CAN protocol: Classical
CAN, CAN FD tolerant and CAN FD enabled.
CTU CAN FD supports all three implementation types and compliance to each
implementation can be changed via MODE[FDE] and SETTINGS[PEX] registers.
Both of these registers chall be modified only when SETTINGS[ENA] = 0.
Both of these registers shall be modified only when SETTINGS[ENA] = 0.
\end_layout
\begin_layout Standard
......@@ -2726,7 +2726,7 @@ cellcolor{gray}
\begin_inset Text
\begin_layout Plain Layout
SETTING[PEX]
SETTING [PEX]
\begin_inset ERT
status open
......@@ -2985,6 +2985,13 @@ Note When CTU CAN FD is configured as Classical CAN / CAN FD tolerant node,
SETTINGS[NISOFD] register has no effect.
\end_layout
\begin_layout Description
Note According to 10.9.10 of ISO11898-1 2015, CAN FD Enabled implementation
shall not be set to a mode where it behaves as CAN FD tolerant implementation.
It is therefore users responsibility to use this option only for evaluation
/ debugging purposes!
\end_layout
\begin_layout Subsection
Minimum bit time
\end_layout
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment