Commit 678e36f3 authored by Ille, Ondrej, Ing.'s avatar Ille, Ondrej, Ing.

src: Disable auto-clear on read data mux. This should significantly

     decrease power at expense of keeping data in previous value after
     the read has finished (instead of zeroeing). This does not mind since
     read data are defined as unknown from second cycle on after the read!
     So it is not in conflict with documenationt.
parent 1cdb95ac
Pipeline #17615 failed with stages
in 9 seconds
......@@ -389,7 +389,7 @@ begin
DATA_WIDTH => 32,
ADDRESS_WIDTH => 16,
REGISTERED_READ => true,
CLEAR_READ_DATA => true,
CLEAR_READ_DATA => false,
RESET_POLARITY => G_RESET_POLARITY,
SUP_FILT_A => G_SUP_FILTA,
SUP_RANGE => G_SUP_RANGE,
......