Commit 443d73fe authored by Ille, Ondrej, Ing.'s avatar Ille, Ondrej, Ing.

Bug-fix of Filter control register read. Reading value of filter B caused

setting filter C upon sequence of Read/write into control of the same
filter. Frame was then passing through Filter C when Filter B was disabled
and should have been disabled!
Signed-off-by: Ille, Ondrej, Ing.'s avatarIlle, Ondrej, Ing <illeondr@fel.cvut.cz>
parent 707566a5
......@@ -1405,7 +1405,7 @@ begin
when FILTER_CONTROL_ADR =>
data_out_int(3 downto 0) <= filter_A_ctrl;
data_out_int(7 downto 4) <= filter_B_ctrl;
data_out_int(11 downto 8) <= filter_B_ctrl;
data_out_int(11 downto 8) <= filter_C_ctrl;
data_out_int(15 downto 12) <= filter_ran_ctrl;
if (sup_filtA) then
......